Pumping station Aquapump Small

Mono, Basic, GTF 1250

The pumping station for faecal wastewater is suitable for underground installation and is equipped with a backflow preventer for the pressure pipe. The PE tank is resistant to domestic wastewater and includes a pedestrian class polymer cover plate. The pump with multi-vane impeller ensures maximum operating reliability. The components are pre-assembled for final assembly on site. Including openings for inlet. - tank made of PE, resistant to domestic wastewater - with a pedestrian class cover plate made of polymer - including backflow preventer for the pressure pipe - including openings for inlet, ventilation and cable duct - pump/s with multi-vane impeller for maximum operating reliability

  • Including backflow preventer for the pressure pipe
  • Including openings for inlet, ventilation and cable duct
  • With pedestrian class polymer cover plate
Item no. 829850
GTIN 4026092092989
Price group 20

Pumping station Aquapump Small Mono, Basic, GTF 1250
The pumping station for faecal wastewater is suitable for underground installation and is equipped with a backflow preventer for the pressure pipe. The PE tank is resistant to domestic wastewater and includes a pedestrian class polymer cover plate. The pump with multi-vane impeller ensures maximum operating reliability. The components are pre-assembled for final assembly on site. Including openings for inlet. - tank made of PE, resistant to domestic wastewater - with a pedestrian class cover plate made of polymer - including backflow preventer for the pressure pipe - including openings for inlet, ventilation and cable duct - pump/s with multi-vane impeller for maximum operating reliability Type of wastewater: wastewater without sewage Installation situation: underground installation Version: Type of system: Single station Installation: Wet installation Pump control: Float switch Backflow preventer: integrated Delivery state: Pre-mounted for final assembly on site (pumps and sensor system must be fitted on site and control unit must be connected) General characteristics: Colour: black Standard: EN 12050-2 Dimensions: Length: 590 mm Width: 590 mm Height: 830 mm Tank: Inlet max. scoring (DN): 100 mm Pumping volume: 25 l Pressure pipe connection (DN): 50 mm Pressure pipe connection (OD): 63 mm Installation depth: 830 mm Coverage features: Type of cover: Round cover plate Colour of cover: black Length: 615 mm Width: 600 mm Locking: lockable Free passage: 30 mm Pumping device: Pump: GTF 1250 Number of pumps: 1 Max. pumping capacity: 20 m3/h Max. pumping height: 11 m Operating voltage: 230 V Mains frequency: 50 Hz Operating mode: S3 - 50 % Power P1: 1.3 kW Power P2: 0.8 kW Speed: 2,700 U/min Type of fuse required (electrical protection): C 16 A Max. temperature (permanent) of conveyed material: 40 °C Connection type: Schuko (earthed contact) 2-pin Weight: 10 kg Impeller type: Multi-vane impeller Length of mains cable for pump: 10 m Rated current: 5.4 A Protection class (pump): IP 68 (3m) Protection class: I Type of pump connection cable: H07RN-F 3G 1.0 mm2 Temperature monitoring: integrated null: 260 mm null: 160 mm Insulation class: F Control: Motor protection switch: yes
  Title Item no.  
  Title Item no.  
  Title Item no.  
  Title Item no.  
One-handed closure for backflow preventer 680018 Show
Seal for pressure pipe connection 680067 Show
Seal for upper section, from 07/2014 680150 Show
Pump connection with seal and flap 680475 Show
Pump connection Minilift, Aqualift S 680760 Show
Flap housing Mono, with pump connector 680761 Show
Turn fastener for pump connection lock 680762 Show
Cover plate round, incl. screws and seal 680801 Show
Pressure pipe DN 32, GTF 1250 680962 Show
Replacement pump GTF 1250 with float switch, 10 m 680965 Show
Pump hanger GTF 1250, Mono 680968 Show
  • Area of application (ATTR-264): drainage
  • Pump type (ATTR-265): submersible pump
  • Pump shaft position (ATTR-266): vertical
  • Pump design (ATTR-267): Dry rotor pump
  • Pump hydraulics (ATTR-268): single stage
  • Pump suction characteristic (ATTR-269): non-self-priming
  • Pump drive (ATTR-270): E-motor for alternating current
  • Pump casing material (ATTR-272): Polymer
  • Upper tolerance of the operating voltage (+) (ATTR-273): 10  PROZ
  • Lower tolerance of the operating voltage (-) (ATTR-274): 10  PROZ
  • Upper tolerance of the nominal frequency (+) (ATTR-275): 3  PROZ
  • Lower tolerance of the nominal frequency (-) (ATTR-276): 2  PROZ
  • Pump electrical connection (ATTR-277): 1/N/PE 230V
  • Startup circuit for three-phase connection or three-phase current (ATTR-278):
  • Motor pump shaft (ATTR-279): continuous
  • Shaft seal (ATTR-280): RSSR
  • Number of operating pumps (ATTR-281): 1
  • Minimum pumped media temperature (ATTR-282): 0  CEL
  • Maximum operating pressure (Pmax) (ATTR-283): 1,100  HPA
  • Minimum speed for speed adjustment (ATTR-284): no speed adjustment
  • Start-up current (ATTR-285): 14.9  AMP
  • Vertical installation (ATTR-286): yes
  • Pump (ATTR-4): GTF 1250
  • Number of pumps (ATTR-181): 1
  • Impeller type (ATTR-8): Multi-vane impeller
  • Type of pump connection cable (ATTR-N2): H07RN-F 3G 1.0 mm2
  • Type of fuse required (electrical protection) (ATTR-N3): C 16 A
  • Operating mode (ATTR-10): S3 - 50 %
  • Power P1 (ATTR-F4): 1.3  KWT
  • Power P2 (ATTR-F5): 0.8  KWT
  • Speed (ATTR-F2): 2,700  UMIN
  • Operating voltage (ATTR-131): 230  VLT
  • Mains frequency (ATTR-N4): 50  HTZ
  • Rated current (ATTR-N5): 5.4  AMP
  • Max. pumping capacity (ATTR-F7): 20  MQH
  • Max. pumping height (ATTR-F8): 11  MTR
  • Max. temperature (permanent) of conveyed material (ATTR-132): 40  CEL
  • Protection class (ATTR-133): I
  • Connection type (ATTR-N1): Schuko (earthed contact) 2-pin
  • Protection class (pump) (ATTR-125): IP 68 (3m)
  • Length of mains cable for pump (ATTR-11): 10  MTR
  • Temperature monitoring (ATTR-135): integrated
  • Weight (ATTR-191): 10  KGM
  • Insulation class (ATTR-193): F
  • Free passage (ATTR-180): 30  MMT
  • - (ATTR-372): 260  MMT
  • - (ATTR-373): 160  MMT
  • Net weight (ATTR-A3A): 26  KGM
  • Gross weight (ATTR-A3B): 32  KGM
  • Installation depth (ATTR-B2_VB): 830  MMT
  • Type of cover (ATTR-A21): Round cover plate
  • Colour of cover (ATTR-A2A): black
  • Load class (ATTR-A2B):
  • Locking (ATTR-A2D): lockable
  • Length (ATTR-A2M): 615  MMT
  • Width (ATTR-A2N): 600  MMT
  • Type of system (ATTR-2): Single station
  • Installation (ATTR-164): Wet installation
  • Backflow preventer (ATTR-165): integrated
  • Pump control (ATTR-134): Float switch
  • Length (ATTR-A6A): 590  MMT
  • Width (ATTR-A6B): 590  MMT
  • Height (ATTR-A6C): 830  MMT
  • Volume (ATTR-320): 0.5  MTQ
  • Packaging dimension: length (ATTR-325): 800  MMT
  • Packaging dimension: width (ATTR-326): 700  MMT
  • Packaging dimension: height (ATTR-327): 950  MMT
  • Dimensions (ATTR-323): 800X700X950MM
  • Number of packages (ATTR-321): 0
  • Inlet max. scoring (DN) (ATTR-B1E): 100  MMT
  • Pressure pipe connection (DN) (ATTR-B17): 50  MMT
  • Pressure pipe connection (OD) (ATTR-B18): 63  MMT
  • Pumping volume (ATTR-B10): 25  LTR
  • Motor protection switch (ATTR-172): yes
  • Declaration of Performance (DOP) (ATTR-292): 009-098
  • Declaration of conformity (ATTR-303): 009-098-C
  • Test report (ATTR-315): DE91T97Y001
  • Colour (ATTR-102): black
  • Type of wastewater (ATTR-6): wastewater without sewage
  • Standard (ATTR-9): EN 12050-2
  • CE marking (ATTR-A5B): yes
  • Installation situation (ATTR-1): underground installation
  • Delivery state (ATTR-189): Pre-mounted for final assembly on site (pumps and sensor system must be fitted on site and control unit must be connected)
  • Brand (M-ATTR-001): KESSEL
  • Product group (M-ATTR-002): Lifting stations
  • Product type (M-ATTR-003): Pumping station
  • Product family (M-ATTR-004): Aqualift
  • Product name (M-ATTR-005): Aqualift S Basic
  • - (ATTR-370):
  • Country of origin (ATTR-322): DE