Pumping station Aquapump Small
Duo, Basic, STF 1300
The pumping station for faecal wastewater is suitable for underground installations and is equipped with a backflow preventer for the pressure pipe. The PE tank is resistant to domestic wastewater and includes a pedestrian class polymer cover plate. The pump with multi-vane impeller ensures maximum operating reliability. Quick-release closures enable the integrated components to be removed easily. The components are pre-assembled for final assembly on site. Including openings for inlet, ventilation and cable duct.
- Variable connection options
- With quick-release closures for easy removal and cleaning
- Vertically adjustable upper section
Item no. | 828711 |
---|---|
GTIN | 4026092084755 |
Price group | 20 |
Pumping station Aquapump Small Duo, Basic, STF 1300
The pumping station for faecal wastewater is suitable for underground installations and is equipped with a backflow preventer for the pressure pipe. The PE tank is resistant to domestic wastewater and includes a pedestrian class polymer cover plate. The pump with multi-vane impeller ensures maximum operating reliability. Quick-release closures enable the integrated components to be removed easily. The components are pre-assembled for final assembly on site. Including openings for inlet, ventilation and cable duct. Type of wastewater: wastewater with sewage Installation situation: underground installation Version: Type of system: Twin pump station Installation: Dry installation Pump control: Control unit Backflow preventer: integrated General characteristics: Colour: black Standard: EN 12050-1 Dimensions: Length: 615 mm Width: 600 mm Height: 830 mm Tank: Inlet max. scoring (DN): 100 mm Pumping volume: 60 l Pressure pipe connection (DN): 50 mm Pressure pipe connection (OD): 63 mm Coverage features: Type of cover: Round cover plate Colour of cover: black Load class: K 3 (EN 1253-1) Locking: lockable Free passage: 40 mm Pumping device: Pump: STF 1300 Number of pumps: 2 Max. pumping capacity: 21 m3/h Max. pumping height: 10 m Operating voltage: 230 V Mains frequency: 50 Hz Operating mode: S3 - 50 % Power P1: 1.3 kW Power P2: 0.8 kW Speed: 2,650 U/min Type of fuse required (electrical protection): C 16 A Max. temperature (permanent) of conveyed material: 40 °C Connection type: coded plug Weight: 10 kg Impeller type: Multi-vane impeller Length of mains cable for pump: 10 m Rated current: 6 A Protection class (pump): IP 68 (3m) Protection class: I Type of pump connection cable: H07RN-F 3G 1.0 mm2 Temperature monitoring: integrated Insulation class: F Control: Control unit: Basic Operating voltage: 230 V Mains frequency: 50 Hz Self-diagnosis system (SDS): yes Battery buffering: yes Potential-free contact: optional Motor protection switch: yes Protection class control unit: IP 54 Connection type: Schuko (earthed contact) 2-pin Length of mains cable for control unit: 1.45 m Type of level measurement: mechanical Level measurement instrument: Float switch Alarm sensor: Float switch
Title | Item no. |
---|
Title | Item no. |
---|
Title | Item no. |
---|
Title | Item no. |
---|
Catalog Page | |
---|---|
Manuals | |
CAD Data | |
Declaration of Performance | |
Declaration of Conformity |
- Country of origin (ATTR-322): DE
- Area of application (ATTR-264): drainage
- Pump type (ATTR-265): Freestanding pump
- Pump shaft position (ATTR-266): vertical
- Pump design (ATTR-267): Dry rotor pump
- Pump hydraulics (ATTR-268): single stage
- Pump suction characteristic (ATTR-269): non-self-priming
- Pump drive (ATTR-270): E-motor for alternating current
- E-motor, type of startup (ATTR-271): direct
- Pump casing material (ATTR-272): Polymer
- Upper tolerance of the operating voltage (+) (ATTR-273): 10 PROZ
- Lower tolerance of the operating voltage (-) (ATTR-274): 10 PROZ
- Pump electrical connection (ATTR-277): 1/N/PE 230V
- Startup circuit for three-phase connection or three-phase current (ATTR-278):
- Motor pump shaft (ATTR-279): continuous
- Shaft seal (ATTR-280): RSSR
- Number of operating pumps (ATTR-281): 1
- Minimum pumped media temperature (ATTR-282): 0 CEL
- Maximum operating pressure (Pmax) (ATTR-283): 1,000 HPA
- Start-up current (ATTR-285): 14.9 AMP
- Vertical installation (ATTR-286): yes
- Pump (ATTR-4): STF 1300
- Number of pumps (ATTR-181): 2
- Impeller type (ATTR-8): Multi-vane impeller
- Type of pump connection cable (ATTR-N2): H07RN-F 3G 1.0 mm2
- Type of fuse required (electrical protection) (ATTR-N3): C 16 A
- Operating mode (ATTR-10): S3 - 50 %
- Power P1 (ATTR-F4): 1.3 KWT
- Power P2 (ATTR-F5): 0.8 KWT
- Speed (ATTR-F2): 2,650 UMIN
- Operating voltage (ATTR-131): 230 VLT
- Mains frequency (ATTR-N4): 50 HTZ
- Rated current (ATTR-N5): 6 AMP
- Max. pumping capacity (ATTR-F7): 21 MQH
- Max. pumping height (ATTR-F8): 10 MTR
- Max. temperature (permanent) of conveyed material (ATTR-132): 40 CEL
- Protection class (ATTR-133): I
- Connection type (ATTR-N1): coded plug
- Protection class (pump) (ATTR-125): IP 68 (3m)
- Length of mains cable for pump (ATTR-11): 10 MTR
- Temperature monitoring (ATTR-135): integrated
- Weight (ATTR-191): 10 KGM
- Insulation class (ATTR-193): F
- Free passage (ATTR-180): 40 MMT
- Type of cover (ATTR-A21): Round cover plate
- Colour of cover (ATTR-A2A): black
- Load class (ATTR-A2B): K 3 (EN 1253-1)
- Locking (ATTR-A2D): lockable
- Length (ATTR-A6A): 615 MMT
- Width (ATTR-A6B): 600 MMT
- Height (ATTR-A6C): 830 MMT
- Volume (ATTR-320): 0.9 MTQ
- Packaging dimension: length (ATTR-325): 1,200 MMT
- Packaging dimension: width (ATTR-326): 800 MMT
- Packaging dimension: height (ATTR-327): 954 MMT
- Dimensions (ATTR-323): 90X90X95 CM
- Number of packages (ATTR-321): 0
- Type of system (ATTR-2): Twin pump station
- Installation (ATTR-164): Dry installation
- Backflow preventer (ATTR-165): integrated
- Pump control (ATTR-134): Control unit
- Inlet max. scoring (DN) (ATTR-B1E): 100 MMT
- Pressure pipe connection (DN) (ATTR-B17): 50 MMT
- Pressure pipe connection (OD) (ATTR-B18): 63 MMT
- Pumping volume (ATTR-B10): 60 LTR
- Gross weight (ATTR-A3B): 51 KGM
- Control unit (ATTR-S2): Basic
- Self-diagnosis system (SDS) (ATTR-S5): yes
- Battery buffering (ATTR-S6): yes
- Potential-free contact (ATTR-S11): optional
- Length of mains cable for control unit (ATTR-S12): 1.5 MTR
- Connection type (ATTR-S19): Schuko (earthed contact) 2-pin
- Operating voltage (ATTR-S13): 230 VLT
- Mains frequency (ATTR-S14): 50 HTZ
- Protection class control unit (ATTR-S4): IP 54
- Alarm sensor (ATTR-S1): Float switch
- Type of level measurement (ATTR-7A): mechanical
- Motor protection switch (ATTR-172): yes
- - (ATTR-S21):
- - (ATTR-S22):
- - (ATTR-S23):
- Colour (ATTR-102): black
- Standard (ATTR-9): EN 12050-1
- Declaration of Performance (DOP) (ATTR-292): 009-086
- Type of wastewater (ATTR-6): wastewater with sewage
- Installation situation (ATTR-1): underground installation
- Brand (M-ATTR-001): KESSEL
- Product group (M-ATTR-002): Lifting stations
- Product type (M-ATTR-003): Pumping station
- Product family (M-ATTR-004): Aqualift
- Product name (M-ATTR-005): Aqualift F Basic
- - (ATTR-370):
- Level measurement instrument (ATTR-7B): Float switch