Skip to main content

Pump motor SPF 1500 / 400 V S1

Item no. 28065
GTIN 4026092058848
Price group 90

Type of wastewater: wastewater with sewage Pumping device: Pump: SPF 1500 Max. pumping capacity: 40 m3/h Max. pumping height: 8 m Operating voltage: 400 V Mains frequency: 50 Hz Operating mode: S1 Power P1: 1.4 kW Power P2: 1.1 kW Speed: 1,415 U/min Max. temperature (permanent) of conveyed material: 40 °C Connection type: Direct connection Length of mains cable for pump: 5 m Rated current: 2.7 A Protection class (pump): IP 68 (3m/48h) Protection class: I Type of pump connection cable: H07RN-F 7G 1.5 mm2 Temperature monitoring: controlled via control unit run dry safe: yes
  Title Item no.  
  Title Item no.  
  Title Item no.  
  Title Item no.  
Catalog Page
Test Reports and Certificates
  • Type of wastewater (ATTR-6): wastewater with sewage
  • Net weight (ATTR-A3A): 27  KGM
  • Gross weight (ATTR-A3B): 29  KGM
  • TÜV test mark (ATTR-376): ID 1111241940
  • Pump (ATTR-4): SPF 1500
  • Type of pump connection cable (ATTR-N2): H07RN-F 7G 1.5 mm2
  • Operating mode (ATTR-10): S1
  • Power P1 (ATTR-F4): 1.4  KWT
  • Power P2 (ATTR-F5): 1.1  KWT
  • Speed (ATTR-F2): 1,415  UMIN
  • Operating voltage (ATTR-131): 400  VLT
  • Mains frequency (ATTR-N4): 50  HTZ
  • Rated current (ATTR-N5): 2.7  AMP
  • Max. pumping capacity (ATTR-F7): 40  MQH
  • Max. pumping height (ATTR-F8): 8  MTR
  • Max. temperature (permanent) of conveyed material (ATTR-132): 40  CEL
  • Protection class (ATTR-133): I
  • Connection type (ATTR-N1): Direct connection
  • Protection class (pump) (ATTR-125): IP 68 (3m/48h)
  • Length of mains cable for pump (ATTR-11): 5  MTR
  • Temperature monitoring (ATTR-135): controlled via control unit
  • run dry safe (ATTR-137): yes
  • Country of origin (ATTR-322): DE