The premium backwater pumping station for faecal and non-faecal wastewater is equipped with a pump and a motor-driven closure system. The pipe cross-section is normally open. In case of backwater, the motor-driven closure system is closed automatically. During the backwater phase, the water drains via the pump with integrated macerator. The station is controlled by a user-friendly control unit, which is optionally integrated in the building management system via a potential-free contact, or alarm and collective fault messages can be output via a GSM interface.

  • Backwater pumping station: uses the natural fall to the sewer - pump is only used for backwater
  • Flexible installation, different covers with drain function available for installation in the floor slab
  • Quiet and energy-saving
Item no. 24150
GTIN 4026092046500
Price group 30

    Backwater pumping station, Pumpfix F DN 150, exposed
    The premium backwater pumping station for faecal and non-faecal wastewater is equipped with a pump and a motor-driven closure system. The pipe cross-section is normally open. In case of backwater, the motor-driven closure system is closed automatically. During the backwater phase, the water drains via the pump with integrated macerator. The station is controlled by a user-friendly control unit, which is optionally integrated in the building management system via a potential-free contact, or alarm and collective fault messages can be output via a GSM interface. Type of wastewater: wastewater with sewage Installation situation: exposed drainage pipe Version: Emergency closure: yes Pump control: Control unit Delivery state: Pre-mounted for final assembly on site (pumps and sensor system must be fitted on site and control unit must be connected) Number of motor-driven backwater flaps: 1 General characteristics: Nominal size (DN): 150 Outer diameter (OD): 160 Colour: black Approval: Z-53.2-388 Dimensions: Length: 656 mm Width: 350 mm Height: 422 mm Drain body: Socket version: including spigot and socket Coverage features: Type of cover: Protective cover Cover material: Polymer Colour of cover: transparent Length: 542 mm Width: 350 mm Height: 165 mm Locking: Clip closure Pumping device: Pump: SPZ 1000 Number of pumps: 1 Max. pumping capacity: 11.5 m3/h Max. pumping height: 10 m Operating mode: S3 - 50 % Power P1: 1.2 kW Power P2: 0.69 kW Speed: 2,800 U/min Type of fuse required (electrical protection): C 16 A Max. temperature (permanent) of conveyed material: 40 °C Connection type: coded plug Weight: 10 kg Impeller type: Macerator Length of mains cable for pump: 5 m Rated current: 5.2 A Protection class (pump): IP 68 (3m/48h) Protection class: I Type of pump connection cable: H07RN-F 3G 1.0 mm2 Temperature monitoring: integrated Cos phi - power factor: 0.97 Insulation class: F Vertical drop between inlet and outlet: 9 mm Motor type: KSM 140 Protection class motor: IP 68 (3m/48h) Protection class probe: IP 68 (3m/48h) Control: Control unit: Comfort Operating voltage: 230 V Mains frequency: 50 Hz Self-diagnosis system (SDS): yes Battery buffering: yes Multi-line display: yes Log book function: yes USB interface: yes GSM interface: yes Potential-free contact: optional Protection class control unit: IP 54 Length of mains cable for control unit: 1.4 m Type of level measurement: optical Level measurement instrument: optical probe Alarm sensor: optical probe

    Installation Video

      Title Item no.  
      Title Item no.  
      Title Item no.  
    Remote signal generator 20 m cable, 2x0.75 q 20162 Show
    Clearance code for potential-free contact 80077 Show
    10 m probe cable extension set 80889 Show
    Cable extension set for motor 10 m 80890 Show
    Cable prolongation set for pump 10 m 80891 Show
      Title Item no.  
    Pump cover inlet side 28052 Show
    Pumpfix F Premium Komf. Cover outlet s. 28056 Show
    Vent for Pumpfix Premium 28060 Show
    Active carbon filter 28061 Show
    Pumpfix F Control Unit Komfort - IP 54 28071 Show
    Replacement pump AqualiftF/Pumpfix F 28351 Show
    One-handed closure for backflow preventer 680018 Show
    Battery 9 V block 680034 Show
    Flap holder for motor-driven and mechanical flap 680101 Show
    Pressure pipe connection with backflow preventer 680104 Show
    Gasket set (Pumpfix, Ecolift) 70319 Show
    Motor-driven backwater flap Premium 80038 Show
    Insert part f. motor-driven flap Premium 80039 Show
    Staufix FKA drive motor (KSM 140) 5m 80076 Show
    Replacement set optical probe 80888 Show
    Adapter set optical probe 80892 Show
    FKA Staufix Protective cover 83031 Show
    FKA Staufix transition piece 83032 Show
    Staufix Premium Spigot DN 150 83083 Show
    Staufix Premium Socket DN 150 83087 Show
    • Installation situation (ATTR-1): exposed drainage pipe
    • Country of origin (ATTR-322): DE
    • Area of application (ATTR-264): drainage
    • Pump type (ATTR-265): Freestanding pump
    • Pump shaft position (ATTR-266): vertical
    • Pump design (ATTR-267): Dry rotor pump
    • Pump hydraulics (ATTR-268): single stage
    • Pump suction characteristic (ATTR-269): non-self-priming
    • Pump drive (ATTR-270): E-motor for alternating current
    • E-motor, type of startup (ATTR-271): direct
    • Pump casing material (ATTR-272): Polymer
    • Upper tolerance of the nominal frequency (+) (ATTR-275): 3  PROZ
    • Lower tolerance of the nominal frequency (-) (ATTR-276): 2  PROZ
    • Pump electrical connection (ATTR-277): 1/N/PE 230V
    • Motor pump shaft (ATTR-279): continuous
    • Shaft seal (ATTR-280): RSSR
    • Minimum pumped media temperature (ATTR-282): 0  CEL
    • Maximum operating pressure (Pmax) (ATTR-283): 1,000  HPA
    • Minimum speed for speed adjustment (ATTR-284): no speed adjustment
    • Start-up current (ATTR-285): 14.9  AMP
    • Vertical installation (ATTR-286): yes
    • Pump (ATTR-4): SPZ 1000
    • Number of pumps (ATTR-181): 1
    • Impeller type (ATTR-8): Macerator
    • Type of pump connection cable (ATTR-N2): H07RN-F 3G 1.0 mm2
    • Type of fuse required (electrical protection) (ATTR-N3): C 16 A
    • Max. permissible switching frequency (ATTR-162): 20  1PH
    • Operating mode (ATTR-10): S3 - 50 %
    • Power P1 (ATTR-F4): 1.2  KWT
    • Power P2 (ATTR-F5): 0.7  KWT
    • Speed (ATTR-F2): 2,800  UMIN
    • Rated current (ATTR-N5): 5.2  AMP
    • Max. pumping capacity (ATTR-F7): 11.5  MQH
    • Max. pumping height (ATTR-F8): 10  MTR
    • Max. temperature (permanent) of conveyed material (ATTR-132): 40  CEL
    • Protection class (ATTR-133): I
    • Connection type (ATTR-N1): coded plug
    • Protection class (pump) (ATTR-125): IP 68 (3m/48h)
    • Length of mains cable for pump (ATTR-11): 5  MTR
    • Temperature monitoring (ATTR-135): integrated
    • Weight (ATTR-191): 10  KGM
    • Cos phi - power factor (ATTR-192): 1.0
    • Insulation class (ATTR-193): F
    • Expected service life (hours of operation) (ATTR-194): 5,000  HUR
    • Expected service life (number of switching cycles) (ATTR-195): 150,000
    • Nominal size (DN) (ATTR-118): 150
    • Outer diameter (OD) (ATTR-147): 160
    • Net weight (ATTR-A3A): 22.3  KGM
    • Gross weight (ATTR-A3B): 22.4  KGM
    • Emergency closure (ATTR-153): yes
    • Pump control (ATTR-134): Control unit
    • Socket version (ATTR-233): including spigot and socket
    • Length (ATTR-A6A): 656  MMT
    • Width (ATTR-A6B): 350  MMT
    • Height (ATTR-A6C): 422  MMT
    • Volume (ATTR-320): 0.1  MTQ
    • Packaging dimension: length (ATTR-325): 785  MMT
    • Packaging dimension: width (ATTR-326): 385  MMT
    • Packaging dimension: height (ATTR-327): 465  MMT
    • Dimensions (ATTR-323): 790X400X490MM
    • Number of packages (ATTR-321): 1
    • Control unit (ATTR-S2): Comfort
    • Self-diagnosis system (SDS) (ATTR-S5): yes
    • Battery buffering (ATTR-S6): yes
    • Multi-line display (ATTR-S7): yes
    • Log book function (ATTR-S8): yes
    • USB interface (ATTR-S9): yes
    • GSM interface (ATTR-S10): yes
    • Potential-free contact (ATTR-S11): optional
    • Length of mains cable for control unit (ATTR-S12): 1.4  MTR
    • Operating voltage (ATTR-S13): 230  VLT
    • Mains frequency (ATTR-S14): 50  HTZ
    • Protection class control unit (ATTR-S4): IP 54
    • Alarm sensor (ATTR-S1): optical probe
    • Type of level measurement (ATTR-7A): optical
    • Level measurement instrument (ATTR-7B): optical probe
    • Type of cover (ATTR-A21): Protective cover
    • Colour of cover (ATTR-A2A): transparent
    • Locking (ATTR-A2D): Clip closure
    • Cover material (ATTR-A2E): Polymer
    • Length (ATTR-A2M): 542  MMT
    • Width (ATTR-A2N): 350  MMT
    • Height (ATTR-A2P): 165  MMT
    • Declaration of Performance (DOP) (ATTR-292): 009-040
    • Declaration of conformity (ATTR-303): 009-567
    • Protection strategy (ATTR-311): Individual protection
    • Type of wastewater (ATTR-6): wastewater with sewage
    • Position relative to sewer (ATTR-309): Gradient to the sewer
    • Function in the event of backwater (ATTR-312): Drains in the event of backwater
    • Protection class probe (ATTR-175): IP 68 (3m/48h)
    • Colour (ATTR-102): black
    • Protection class motor (ATTR-174): IP 68 (3m/48h)
    • Motor type (ATTR-120B): KSM 140
    • Approval (ATTR-A5): Z-53.2-388
    • Number of motor-driven backwater flaps (ATTR-3A): 1
    • External monitoring (ATTR-A8): LGA
    • Vertical drop between inlet and outlet (ATTR-176): 9  MMT
    • Delivery state (ATTR-189): Pre-mounted for final assembly on site (pumps and sensor system must be fitted on site and control unit must be connected)
    • Brand (M-ATTR-001): KESSEL
    • Product group (M-ATTR-002): Hybrid lifting stations
    • Product type (M-ATTR-003): Backwater pumping station
    • Product family (M-ATTR-004): Pumpfix
    • Product name (M-ATTR-005): Pumpfix F